LEEYD Logo
Industrial Power Systems
CURRENT MEASUREMENT SINCE 1985

Hall Current Sensors for Industrial Power Systems

Isolated current measurement solutions for DC, AC, pulse, and complex waveforms. Explore open-loop, closed-loop, split-core, and 4–20mA output models for currents from 1A to 80,000A.

Quick Selection Guide

Find the Right Hall Current Sensor

Compare current requirements, sensor technology, installation structure, and output options—or send us your requirements for model recommendation.

01

Current Requirements

DC AC Pulse 1A–80,000A Complex Waveforms
02

Sensor Technology

Open Loop Closed Loop Current Transmitter Switching Sensor
03

Installation

Solid Core Split Core PCB Mount Busbar Mount Large Aperture
04

Output Options

Voltage Output Current Output 4–20mA Switching Output Custom Configuration

Not Sure Which Model to Choose?

Send us your current type and range, conductor size, output signal, supply voltage, accuracy requirements, and application.

Current and Voltage Sensor Portfolio

Explore six sensor families for isolated current and voltage measurement, signal conversion, high-precision measurement, and switching-output applications.

LD-CS500E

Open-Loop Hall Current Sensors

Open-loop Hall current sensors for isolated measurement of DC, AC, pulse, and complex waveforms across a broad range of current and installation requirements.

DC / AC / Pulse Single-Supply Models Dual-Supply Models

Representative Models:

LD-CS040GT5, LD-CS500ET5, LD-CS2000EK2T5, LD-CS500E, LD-CS2000EK2, LD-CS6000KAC

LD-CSM1000LTC

Closed-Loop Hall Current Sensors

Closed-loop Hall current sensors for isolated measurement in applications requiring improved accuracy, linearity, response, and measurement stability.

Closed-Loop Measurement Single-Supply Models Dual-Supply Models

Representative Models:

LD-CSM025AYT2, LD-CSM100LAT2, LD-CSM005A, LD-CSM300LT, LD-CSM1000LTC, LD-CSM3000LTF

LD-CS500ET

Hall Current Transmitters

Hall-effect current transmitters that measure DC or AC current under electrical isolation and convert the measured signal into a proportional DC output for monitoring and control systems.

DC Transmitter Models AC Transmitter Models Model-Dependent Output

Representative Models:

LD-CS500ET, LD-CS2000EK2T, LD-CS10000KCT, LD-A-CS300ET, LD-A-CS500EK1T, LD-A-CS3000KAT

LD-DCSM500LFBH

Fluxgate High-Precision Sensors

Fluxgate sensors for high-precision isolated current and voltage measurement in applications requiring enhanced accuracy and measurement stability.

Fluxgate Technology Current Measurement Voltage Measurement

Representative Models:

LD-DCSM050LRSH/5V, LD-DCSM100LRCH, LD-DCSM300LDGH, LD-DCSM500LFBH, LD-DVSM3000EV/5V

LD-VSM800D

Voltage Sensors

Isolated voltage sensors that convert measured voltage into a proportional output signal for electrical monitoring, control, and data-acquisition applications.

Voltage Measurement Electrical Isolation Proportional Output

Representative Models:

LD-VSM025A, LD-VSM800D, LD-VSM1200DP, LD-VS1000AT2, LD-VS1000AT2-P, LD-A-VSM800DAT

LD-KCS500ET

Switching-Output Sensors

Switching-output sensors for current detection, threshold monitoring, alarm signaling, and overcurrent protection applications.

Threshold Detection Switching Output Alarm & Protection

Representative Models:

LD-KCS500ST, LD-KCS500ET, LD-KCS500EDT, LD-KCS500BT, LD-A-KCS030GET, LD-A-KCS030GBT

Not Sure Which Sensor Family Fits Your Application?

Compare the six sensor families by measurement target, sensing principle, and signal-conversion function.

Compare Sensor Families

Use this overview to identify the appropriate sensor family. Final model selection should be based on the measurement range, output signal, supply voltage, conductor dimensions, accuracy, and installation requirements.

Sensor Family Measurement Target Primary Function Available Configurations Representative Models
Open-Loop Hall Current Sensors DC, AC, pulse and complex-waveform current General isolated current measurement Single-supply and dual-supply models LD-CS500ET5, LD-CS500E, LD-CS2000EK2
Closed-Loop Hall Current Sensors Current, depending on model Isolated measurement for applications requiring improved accuracy, linearity and response Single-supply and dual-supply models LD-CSM100LAT2, LD-CSM300LT, LD-CSM1000LTC
Hall Current Transmitters DC or AC current Convert measured current into a proportional DC output signal DC transmitter and AC transmitter models LD-CS500ET, LD-CS2000EK2T, LD-A-CS300ET
Fluxgate High-Precision Sensors Current or voltage High-precision isolated measurement Current-measurement and voltage-measurement models LD-DCSM100LRCH, LD-DCSM500LFBH, LD-DVSM3000EV/5V
Voltage Sensors Voltage Isolated voltage measurement and signal conversion Model-dependent configurations LD-VSM025A, LD-VSM800D, LD-VS1000AT2
Switching-Output Sensors Current or other detection signals, depending on model Threshold detection, alarm signaling and protection DC, AC and model-dependent switching configurations LD-KCS500ET, LD-KCS500BT, LD-A-KCS030GET

* Product families and technical characteristics may overlap. For example, a current transmitter may use an open-loop Hall principle, while selected sensor models may use detachable structures or different output configurations. Always confirm the complete datasheet before model selection or ordering.

Need Help Selecting a Specific Model?

Send us the measurement target, rated range, conductor dimensions, required output, supply voltage, accuracy requirement, and application. Our team will help identify a suitable sensor family and model.

Built for Application-Specific Electrical Measurement

Sensor solutions for isolated current and voltage measurement, signal conversion, precision measurement, and switching-output applications.

Broad Sensor Portfolio

Our portfolio includes open-loop and closed-loop Hall current sensors, current transmitters, fluxgate high-precision sensors, voltage sensors, and switching-output sensors.

Current and Voltage Measurement

Available product families support isolated measurement of DC, AC, pulse, complex-waveform current, and voltage signals, depending on the selected model.

Multiple Signal Functions

Product configurations include proportional voltage or current output, converted DC signals, and switching outputs for monitoring, control, protection, and data-acquisition applications.

Engineering Review and Model Matching

Rated range, output signal, supply voltage, conductor dimensions, aperture, terminals, accuracy, and mechanical structure can be reviewed according to the application requirements.

Current Measurement Across Industrial Power Applications

Power Conversion & Inverters

Current feedback and monitoring for converters, inverters, rectifiers, and power-electronic equipment.

Energy Storage Systems

Isolated current measurement for battery systems, energy-storage converters, and DC power equipment.

Industrial Drives & Automation

Current sensing for motor drives, servo systems, industrial machinery, and automation equipment.

Rail & Traction Power

Current measurement and monitoring for traction equipment, auxiliary power systems, and railway electrical applications.

Power Distribution & Switchgear

Current monitoring for distribution cabinets, switchgear, protection panels, and electrical control systems.

Test & Measurement Equipment

Isolated current acquisition for test benches, calibration systems, laboratory instruments, and data-acquisition equipment.

Sensor Model Matching for Your Electrical System

With six sensor families and multiple electrical and mechanical configurations, model selection should begin with the actual measurement target, system interface, and installation requirements. Our team can review existing drawings, existing model numbers, or new system specifications to identify a suitable standard model or discuss an adjusted configuration where feasible.

  • Measurement target and signal type
  • Rated and maximum measurement range
  • Required output and receiving equipment
  • Available supply voltage
  • Conductor or busbar dimensions
  • Aperture and installation space
  • Accuracy, linearity, and response requirements
  • Terminals and mounting arrangement
  • Existing-model cross-reference
Engineering Support

Controlled Production and Electrical Verification

Hall sensor production is supported by automated PCB processing, controlled reflow soldering, production-stage electrical checks, and final inspection according to the applicable product and order requirements.

Automated SMT Processing

Automated SMT Processing

Automated equipment supports PCB processing and consistent component placement for sensor assemblies.

Controlled Reflow Soldering

Controlled Reflow Soldering

Controlled reflow processing supports stable and repeatable soldering of sensor PCB assemblies.

Assembly and Electrical Checks

Assembly and Electrical Checks

Sensor assemblies undergo connection, output, and basic functional checks according to the applicable model requirements.

Final Inspection and Packing

Final Inspection and Packing

Product identification, appearance, order-specific details, and packing requirements are checked before shipment.

Technical Resources for Model Evaluation

Request model-specific specifications, dimensional information, and connection details to support sensor selection and system integration.

Model Datasheets

Electrical specifications, supply requirements, output characteristics, accuracy data, and operating conditions for the selected sensor model.

Dimensions & Mounting Information

Product dimensions, aperture sizes, conductor requirements, terminal arrangements, and mounting details for installation review.

Connection & Application Support

Connection diagrams, output-interface information, and application notes for integrating the selected sensor with your system.

Frequently Asked Questions

What is the difference between open-loop and closed-loop Hall current sensors?
Open-loop sensors generally offer a simpler structure and cost-effective measurement across a broad current range. Closed-loop sensors use a compensation principle and are typically selected when higher accuracy, linearity, response speed, or temperature stability is required. Actual performance depends on the selected model.
Can Hall current sensors measure both AC and DC current?
Selected Hall current sensor series can measure DC, AC, pulse, and complex-waveform currents. The supported signal type, measurement range, bandwidth, and response time depend on the sensor family and specific model.
When should I consider a fluxgate current sensor?
Fluxgate sensors are generally considered for applications requiring high accuracy, low offset, strong linearity, and stable measurement of small changes in current. They are commonly evaluated for precision measurement, calibration, test equipment, and high-performance control systems.
What information is needed to select a suitable sensor?
Please provide the measurement target, rated and maximum range, required output, supply voltage, conductor or busbar dimensions, available installation space, accuracy requirements, and application conditions. An existing model number or drawing can also help with cross-reference evaluation.
What output signals are available?
Depending on the product family and model, available configurations may include proportional voltage output, current output, converted DC signals, or switching outputs. The output must be matched with the receiving equipment, such as a controller, PLC, meter, or data-acquisition system.
Can electrical or mechanical configurations be adjusted?
Aperture size, conductor arrangement, terminals, mounting structure, supply, output, and other specifications may be reviewed for a particular project. Feasibility depends on the technical requirements, order quantity, validation needs, and selected sensor platform.

Request a Sensor Model Recommendation

Share your measurement, output, supply, and installation requirements. Our team will review the application and recommend a suitable standard sensor model or discuss an adjusted configuration where feasible.

Call Us

+8618913393116

Headquarters

701 Tianyin Avenue, Jiangning District, Nanjing, China