LEEYD Logo

LD-96E Multifunction Power Meter

The LD-96E measures three-phase voltage, current, power, power factor, frequency and energy for power distribution panels and industrial equipment.

Panel Size
96 × 96 mm
Display
Backlit LCD
System
Three-phase, 3-wire / 4-wire
Communication
RS485 / Modbus RTU*

*Communication and I/O options vary by configuration.

Technical Specifications

Review the measurement functions, electrical ratings and installation requirements. Communication channels and additional I/O depend on the ordered configuration.

Measurement Functions

Parameter Specification
Phase voltage UA, UB, UC and average
Line-to-line voltage UAB, UBC, UCA and average
Current IA, IB, IC and average
Active power Per-phase and total
Reactive power Per-phase and total
Apparent power Per-phase and total
Power factor Per-phase and average
Frequency System frequency
Active / reactive energy Import, export, total and net values
Statistics Maximum and minimum values
Additional functions* Voltage/current harmonics, 2nd–31st; limit alarms and alarm event records

*Additional functions depend on configuration.

Electrical Inputs & Supply

Parameter Specification
Wiring system Three-phase, 3-wire / 4-wire
Sampling AC sampling
Current input 0–5 A AC
CT-scaled primary current Up to 9999 A
Continuous current overload 2 × rated current
Voltage circuit burden <0.2 VA
Current circuit burden <0.1 VA
Auxiliary supply 85–265 V AC, 50 Hz; or 85–264 V DC
Power consumption <3 W

Specify the required voltage input and CT/PT ratios when ordering. Primary-side values use the configured transformer ratios; they are not direct-input ratings.

Accuracy, Resolution & Indicated Ranges

Reference conditions: 50 Hz, 23 °C, 35% relative humidity and a 220 V AC auxiliary supply.

Parameter Accuracy Resolution Indicated range
Voltage 0.2% 0.1 V, secondary side See ordered voltage input rating
Current 0.2% 0.001 A, secondary side 0%–300% of CT secondary current*
Active power 0.2% — −9999 to +9999 MW
Reactive power 0.2% — −9999 to +9999 Mvar
Apparent power 0.2% — 0–9999 MVA
Power factor 0.2% 0.001 −1.0 to 0 to +1.0
Frequency 0.2% 0.01 Hz 40–65 Hz
Active energy Class 0.2S 0.01 kWh 0–9,999,999.99 kWh
Reactive energy 0.5% 0.01 kvarh —
Harmonic content** 0.5% 0.01% 0%–100%

*The indicated current range does not define the permissible continuous input. **Harmonic analysis depends on configuration. A dash indicates that no numerical value is published for that entry. On small screens, scroll this table horizontally.

Communication & Additional I/O

Function Specification
Communication RS485, Modbus RTU; half duplex
Cable Two-core shielded twisted pair
Isolation technology Magnetic isolation
Baud rate 1200 / 2400 / 4800 / 9600 bps
Digital inputs According to configuration
Relay outputs According to configuration
Energy pulse output Optically isolated; according to configuration
Analog outputs According to configuration

Confirm the required interface types, channel quantities and output combinations when ordering.

View detailed input and output specifications

Digital Inputs

Input type Dry contact
Input impedance >20 kΩ
Maximum input current 20 mA
Time resolution 20 ms
Isolation withstand 2 kV AC

Use the digital-input connection instructions supplied for the ordered configuration.

Relay Outputs

Contact type Normally open, potential-free
Maximum switching voltage 277 V AC / 30 V DC
Maximum switching current 6 A
Isolation withstand 2 kV AC

Energy Pulse Output

Output type Optically isolated
Default pulse constant 8000 imp/kWh
Pulse constant options 1000–36000 imp/kWh; specify when ordering
Isolation withstand 2 kV AC

Analog Outputs

Current output options 4–20 mA / 0–20 mA / 0–10 mA
Voltage output options 0–5 V / 1–5 V / 0–10 V
Current output load ≤500 Ω
Voltage output load ≥500 Ω
Isolation withstand 2 kV AC

Mechanical & Environmental Data

Parameter Specification
Front panel size 96 × 96 mm
Overall dimensions 96 × 96 × 76 mm
Panel cutout 92 × 92 mm
Mounting Panel mounting with fixing brackets
Display Backlit LCD with four front-panel keys
Protection rating IP20
Weight Approx. 400 g
Operating temperature −10 to +55 °C
Recommended operating temperature 0 to +45 °C
Storage temperature −25 to +70 °C
Relative humidity 5%–95%, non-condensing
Temperature drift <50 ppm/°C
Long-term stability 0.4‰ per year
Standards Referenced
Measurement references GB/T 13978-2008; GB/T 13850-1998; GB/T 17883-1999; IEC 61268 (Class 1.0 listed in the manual)
Environmental reference IEC 60068-2
Safety reference IEC 61010
ESD immunity reference IEC 61000-4-2, Level 4
Radiated immunity reference IEC 61000-4-3, Level 4
Electrical fast transient reference IEC 61000-4-4, Level 3
Surge immunity reference IEC 61000-4-5, Level 3

References from the supplied manual; not third-party certification claims or a statement of the latest standard editions.

Dimensions & Wiring

Check the panel cutout, installation space and wiring arrangement before installation. Use the terminal diagram supplied for the ordered configuration.

LD-96E meter showing 96 mm front panel dimensions and 76 mm overall depth
Dimensions — click to enlarge.

Dimensions & Panel Cutout

  • Front panel 96 × 96 mm
  • Overall depth 76 mm
  • Panel cutout 92 × 92 mm

Check the panel cutout and allow additional space behind the panel for terminals and connected cables.

Panel Installation

Insert the meter into the panel cutout and secure it with the supplied fixing brackets. Allow additional space for terminals and connected cables.

The illustration shows the mounting arrangement. Refer to the supplied installation instructions for the selected product.

Panel mounting illustration of a multifunction power meter showing the side fixing bracket
Panel mounting illustration.

Wiring Diagram & Terminal Assignments

LD-96E terminal assignments with three-phase three-wire and four-wire wiring diagrams
Click to enlarge and inspect the terminal markings.

Terminal assignments and available interfaces depend on configuration. Refer to the supplied wiring diagram before making connections.

Technical Documents

Request the datasheet, user manual or wiring details for your required configuration.

Request Technical Documents

Request a Quote for the LD-96E

Send us your required quantity and electrical specifications. We can review the input ratings, auxiliary supply and interface requirements for your application.

Useful Details to Include

  • Three-phase, 3-wire or 4-wire system
  • Voltage input and CT/PT ratios, where applicable
  • Available auxiliary supply
  • Required communication and I/O
  • Quantity and delivery destination

You may also email your requirements to [email protected].