LEEYD Logo
POWER DISTRIBUTION PROTECTION

Zinc Oxide
Surge Arresters

Low-Voltage · 10kV · 35kV

Surge arrester solutions for power distribution systems, switchgear, transformers, and industrial electrical equipment.

Available in multiple electrical ratings, housing structures, and installation configurations according to system and application requirements.

* For model selection, please provide the system voltage, installation location, application, and required quantity.

LEEYD Zinc Oxide Lightning Arresters Collection

Zinc Oxide Surge Arrester Range

Select the product range according to your system voltage. Final model selection should also consider the arrester rated voltage, continuous operating voltage, discharge current, housing structure, and installation requirements.

Low Voltage Arrester
220V / 380V SYSTEMS

Low-Voltage Metal Oxide Surge Arresters

Compact metal oxide surge arresters for low-voltage distribution equipment, switch cabinets, and industrial electrical systems. Available models and electrical characteristics should be confirmed according to the system and installation requirements.

10kV Arrester
10kV POWER SYSTEMS

10kV Zinc Oxide Surge Arresters

Composite-housed zinc oxide surge arresters for 10kV distribution networks, transformers, switchgear, and outdoor electrical installations. Multiple structures and electrical ratings are available for different protection and installation requirements.

35kV Arrester
35kV POWER SYSTEMS

35kV Zinc Oxide Surge Arresters

Zinc oxide surge arresters for 35kV power distribution, substation equipment, transformers, and outdoor electrical systems. Model availability, electrical ratings, housing structure, and mounting requirements should be confirmed for each project.

MODELS & SPECIFICATIONS

Available Surge Arrester Models

Explore available low-voltage, 10kV, and 35kV surge arrester models. Compare electrical ratings and installation dimensions, or send us your existing model and system information for confirmation.

220V / 380V SYSTEMS

Low-Voltage Metal Oxide Surge Arresters

The YH1.5W series is designed for transient overvoltage protection in 220V and 380V low-voltage electrical systems. Its compact structure supports installation in switch cabinets, distribution equipment, control panels, and other industrial electrical assemblies.

Two electrical ratings are available. Confirm the system voltage, connection method, installation space, and required protection characteristics before ordering.

Low-Voltage Surge Arrester Photo
Low-Voltage Surge Arrester Dimensions
Parameter YH1.5W-0.28/1.3 YH1.5W-0.5/2.6
System Voltage 0.22kV 0.38kV
Arrester Rated Voltage* 0.28kV 0.5kV
Continuous Operating Voltage 0.24kV 0.42kV
DC 1mA Reference Voltage 0.6kV 1.2kV
Residual Voltage* 1.3kV 2.6kV
Housing Diameter 56mm 56mm
Overall Height 78±1mm 80±1mm
Terminal Thread M6 M6
10kV POWER SYSTEMS

10kV Zinc Oxide Surge Arrester Models

Multiple electrical and structural configurations are available for 10kV distribution networks, transformers, switchgear, and related electrical equipment. Models may differ in protection characteristics, housing structure, terminals, dimensions, and mounting arrangement.

YH5WS-17/50

YH5WS-17/50

Standard composite-housed configuration

YH5WS-17/50Q

YH5WS-17/50Q

Compact configuration with cable lead

YH5BS-17/50

YH5BS-17/50

Disconnecting and mounting configuration

YH5WS-17/50L

YH5WS-17/50L

Extended housing and mounting configuration

YH5WR-17/45

YH5WR-17/45

Compact in-line terminal configuration

YH5WZ-17/45

YH5WZ-17/45

Available in multiple housing structures

Similar electrical ratings may use different housing, terminal, and mounting configurations. Confirm both electrical characteristics and installation dimensions before ordering.

Model Rated Voltage MCOV DC 1mA Reference Voltage
YH5WS-17/50 17kV 13.6kV 25kV
YH5WS-17/50Q 17kV 13.6kV 25kV
YH5BS-17/50 17kV 13.6kV 25kV
YH5WS-17/50L 17kV 13.6kV 25kV
YH5WR-17/45 17kV 13.6kV 24kV
YH5WZ-17/45 17kV 13.6kV 24kV
YH5WZ-51/134 35kV Surge Arrester
35kV POWER SYSTEMS

YH5WZ-51/134 Zinc Oxide Surge Arrester

Available for 35kV power distribution systems and related outdoor electrical installations. Electrical characteristics, housing dimensions, and mounting configuration should be confirmed according to the protected equipment and project requirements.

System Voltage 35kV
Rated Voltage 51kV
MCOV 40.8kV
DC 1mA Reference Voltage 73kV
Shed Diameter 104/136mm
Overall Height 535mm
MODEL SELECTION

How to Select the Right Surge Arrester

System voltage is only the starting point. A suitable surge arrester should also be selected according to the grounding method, protected equipment, temporary overvoltage conditions, installation environment, and mounting requirements.

Provide the information currently available. If some specifications are not yet confirmed, send us the existing model, nameplate photo, or application details for review.

Electrical System

Provide the nominal system voltage, frequency, and available arrester ratings. If known, include the maximum continuous operating voltage and temporary overvoltage conditions.

System Grounding

Confirm whether the system neutral is effectively grounded, resistance grounded, isolated, or uses another grounding arrangement.

Equipment & Installation

Tell us what equipment requires protection and where the arrester will be installed, such as a transformer, switchgear, distribution line, motor, capacitor bank, or control cabinet.

Environment & Project Details

Provide the installation altitude, ambient temperature, pollution conditions, required housing structure, quantity, and target delivery date where applicable.

APPLICATIONS

Surge Protection for Power Distribution & Electrical Equipment

Our low-voltage, 10kV, and 35kV surge arrester models support overvoltage protection across power distribution systems, electrical equipment, and industrial installations. The appropriate model depends on the system voltage, grounding method, protected equipment, and installation conditions.

Power Distribution Networks

Power Distribution Networks

Surge arresters support the protection of distribution lines and connected electrical equipment against lightning and switching overvoltage.

Transformers Protection

Transformer Protection

Installed near transformer terminals, surge arresters can help limit incoming overvoltage and support transformer insulation protection.

Switchgear & Substations

Switchgear & Substations

Surge arrester configurations are available for medium-voltage switchgear, distribution cabinets, and related substation equipment.

Low-Voltage Electrical Equipment

Low-Voltage Electrical Equipment

Compact low-voltage models are available for switch cabinets, control panels, distribution equipment, and other 220V or 380V electrical systems.

MANUFACTURING & INSPECTION

Surge Arrester Production & Quality Control

From model and specification confirmation to assembly, inspection, and packing, the production process is coordinated according to the selected surge arrester configuration and order requirements.

Available production and inspection processes vary by model. Any required test items, documents, labeling, or packing requirements should be confirmed before production.

Surge Arrester Production Workshop Overview

Production Workshop Overview

Production Workshop
Testing Instrument
Testing Instrument
Production Workshop
Production Workshop
Testing Instrument
FAQ 

Surge Arrester Frequently Asked Questions

Answers to common questions about model selection, replacement, specifications, documents, samples, and ordering.

1. How do I select the right surge arrester model?

Model selection should consider more than the nominal system voltage. Please also confirm the grounding method, maximum continuous operating voltage, protected equipment, installation environment, mounting dimensions, and any existing protection requirements.

If you are unsure, send us the system information, existing model, nameplate photo, or technical drawing. We will review the available information and help identify a suitable option.

2. What information should I provide for model confirmation?

For a faster review, please provide the following information where available:

  • System voltage and frequency
  • Grounding method
  • Protected equipment
  • Required rated voltage and MCOV
  • Indoor or outdoor installation
  • Mounting dimensions or drawing
  • Existing model or nameplate photo
  • Required quantity and delivery date

You do not need to have every specification confirmed before contacting us.

3. Can you help replace an existing surge arrester model?

Yes. Please send the complete model number, a clear nameplate photo, full product photos, terminal and mounting details, and installation dimensions.

We will compare the available electrical and mechanical information with our existing models. A replacement should not be confirmed by appearance or system voltage alone.

4. What voltage ranges and models are currently available?

Our current range covers low-voltage models for 220V and 380V systems, multiple 10kV zinc oxide surge arrester configurations, and a 35kV model range.

Availability, electrical ratings, housing structure, terminals, and mounting dimensions should be confirmed for the required model and order quantity.

5. Can you provide drawings, datasheets, or test documents?

Available product drawings, dimensional information, technical datasheets, test data, and compliance documents can be provided according to the selected model.

Document availability varies by model. If your project requires a specific standard, test item, language, or document format, please confirm the requirement before ordering.

6. Are samples available before a production order?

Sample availability depends on the model, current stock, quantity, and any required configuration. Standard models may be available more quickly, while special structures or specifications may require additional preparation.

Send us the required model and application information so we can confirm the sample cost and estimated lead time.

7. What is the typical production lead time?

Lead time depends on the selected model, order quantity, current production schedule, document requirements, and whether any special configuration is required.

Please provide the model, quantity, required documents, and target delivery date. We will confirm the available production and shipment schedule before the order is placed.

Request a Surge Arrester Quote

Send us the model, system information, or existing product details available at this stage. We will review the requirements and confirm the suitable available model, required documents, pricing, and estimated lead time.

Headquarters

701 Tianyin Avenue, Jiangning District, Nanjing, China

Your information is secure. We do not share data with third parties.